  1. In order to keep your SpeedTreater-TX in tip-top shape, remove the nozzle after use, daily.
    • In order to keep your SpeedTreater-TX in tip-top shape, remove the nozzle after use, daily.

    • Put the nozzle and filter in a small glass bottle filled with Cloggy No More cleaning solution.

    • Alternatively, a 50/50 mix of distilled water and Simple Green can be used.

    • The SpeedTreater-TX allows you to flush the lines easily, without wasting pretreatment.

    • We recommend flushing the lines at the end of the week, and before known periods of downtime.

  2. Open the panel at the back of the machine by turning the silver knob counter-clockwise. Remove the catch basin. Check how full the catch basin is. Empty it if necessary. Remove the nozzle by unscrewing the nut counter-clockwise. It will drop down from the valve along with the filter and plastic washers.
    • Open the panel at the back of the machine by turning the silver knob counter-clockwise.

    • Remove the catch basin. Check how full the catch basin is. Empty it if necessary.

    • Remove the nozzle by unscrewing the nut counter-clockwise. It will drop down from the valve along with the filter and plastic washers.

  3. Drop the nozzle and the filter into a small glass cup or bottle filled with Cloggy No More. Since the catch basin is removed during this process, a few drops of pretreatment or solution might drip on the inside of the machine. Make sure to clean up any excess liquid. Now replace the catch basin.
    • Drop the nozzle and the filter into a small glass cup or bottle filled with Cloggy No More.

    • Since the catch basin is removed during this process, a few drops of pretreatment or solution might drip on the inside of the machine. Make sure to clean up any excess liquid.

    • Now replace the catch basin.

    • Do NOT push the catch basin back in with any force. Just slide it back in gently. Make sure it sits flat.

  4. You will need two containers to perform the maintenance properly, an empty container and a container with a flushing solution. We recommend that you use 1/2 cup of Simple Green mixed with a gallon of distilled water.
    • You will need two containers to perform the maintenance properly, an empty container and a container with a flushing solution. We recommend that you use 1/2 cup of Simple Green mixed with a gallon of distilled water.

    • Make sure the catch basin is in place under the valve before flushing the machine. It does not matter whether the nozzle is screwed on or not.

  5. Take the IN hose out of your pretreatment container and leave it exposed Push and hold the PURGE button until most of the pretreatment left in the machine cycles back into your pretreatment container.
    • Take the IN hose out of your pretreatment container and leave it exposed

    • Push and hold the PURGE button until most of the pretreatment left in the machine cycles back into your pretreatment container.

    • The sound of the the pump will change once it runs out of liquid.

  6. Put the in hose in the flushing solution and the out house in the empty container Hold the PURGE button for 20-30 seconds. The machine will cycle the solution through the pump. Both hoses should be filled with solution at this point.
    • Put the in hose in the flushing solution and the out house in the empty container

    • Hold the PURGE button for 20-30 seconds. The machine will cycle the solution through the pump. Both hoses should be filled with solution at this point.

    • Remove and empty the catch basin. Then put the catch basin back in.

    • Leave the machine with tubes in the containers until you are ready to use the machine again.

  7. Slide open the drawer, and pull the shield out towards you all the way. Clean any excess pretreatment or liquid from the shield, particularly in the back where the flushing occurs. The shirt holder and shield can be removed for a more  thorough cleaning by removing the small knobs on the underside of the drawer.
    • Slide open the drawer, and pull the shield out towards you all the way.

    • Clean any excess pretreatment or liquid from the shield, particularly in the back where the flushing occurs.

    • The shirt holder and shield can be removed for a more thorough cleaning by removing the small knobs on the underside of the drawer.

  8. Open the panel in the back of the machine. Put the nozzle assembly back together. The nozzle goes first into the nut, then a washer, then the filter (lip-side down), and then another washer over the lip of the filter.
    • Open the panel in the back of the machine.

    • Put the nozzle assembly back together.

    • The nozzle goes first into the nut, then a washer, then the filter (lip-side down), and then another washer over the lip of the filter.

    • Refer to Step 9 for an illustrated diagram.

    • Screw the assembly back into the valve.

    • You can tighten the nut by hand; then use a wrench or pliers to tighten nut slightly past hand tight (Do not over tighten.)

    • Make sure the nozzle is oriented correctly by using the nozzle alignment tool provided.

  9. Here's how to reassemble the valve.
    • Here's how to reassemble the valve.

  10. Check how full the catch basin is. Empty it if necessary. Then put it back in the chamber. Remove the IN hose from the container of flushing solution and leave it exposed. Leave the OUT hose in the waste container. Push and hold the PURGE button until all of the solution has been cycled back into the waste container.
    • Check how full the catch basin is. Empty it if necessary. Then put it back in the chamber.

    • Remove the IN hose from the container of flushing solution and leave it exposed. Leave the OUT hose in the waste container.

    • Push and hold the PURGE button until all of the solution has been cycled back into the waste container.

  11. Put the IN hose into the pretreatment container. Hold the PURGE button for about 5 seconds just until pretreatment flows through out tube. You will hear solution being sprayed against the catch basin. When machine is full, put the OUT hose in the pretreatment.
    • Put the IN hose into the pretreatment container.

    • Hold the PURGE button for about 5 seconds just until pretreatment flows through out tube. You will hear solution being sprayed against the catch basin.

    • When machine is full, put the OUT hose in the pretreatment.

    • Your SpeedTreater-TX is now ready for spraying.

    • This flushing procedure should also be performed when switching from one type of pretreatment to another.